Ensuring Safe Shorepower

Using 15-amp adaptors requires more than just matching the right plugs.

5

Power pedestals are handy and safe when they match the power requirements of the boat. Thirty amps for a 30-amp boat. Fifty amps for a 50-amp boat. But what about when they don’t match? Weaving your way through the requirements can be complicated, often difficult, and sometimes just impossible. We saw some scary stuff while collecting images for this article, and we didn’t have to walk far.

One of the first things I did when downsizing from a cruising cat to a 24-foot trimaran was add a simple solar system to keep the battery charged and free us from shorepower. I could have installed a small AC-powered battery charger, but this worked better for my situation.

As a side note, there are some caveats to going the solar-only route. Some setups can eventually reduce battery capacity (see “Fighting Sulfation in AGM Batteries,” PS May 2015). However, since I don’t have a lot of power-hungry systems on this boat, and I rarely let the capacity drop below 85 percent, this is not a major issue for me. I also have the option of connecting a portable battery charger to bring the batteries up to full charge as needed to prevent sulfation.

Getting back to adapters. Going up in amperage from the plug to the boat primarily means you can’t run all your appliances at once without popping a pedestal breaker. A 50-amp boat plugged into a 30-amp circuit may have to choose between running the dryer and air conditioning, or at least delay laundry until the battery charger has dropped down from peak load.

You will also be operating closer to the current-carrying capacity of the pedestal and attached plug and converter. This means special precautions are in order. The adapter must be fitted with weatherproof connectors at both ends—which is very rare. The plugs must be clean and greased to prevent corrosion. Periodically rinse male plugs with tap water and dry them to prevent salt buildup. There’s not much you can do about the female part, other than keep it protected at all times and clean off the male part.

The locking rings are often broken or missing. They are a $12 replacement item. The replacements will slip over the end, but require considerable effort. It helps if the rings are warm and lubricated. (A little KY jelly or non-petroleum grease works.) If the receptacle thread is broken, contact the marina to get it fixed.

Going down in amperage from the receptacle directly to the boat (or other tool or accessory) creates a different kind of risk. A 50-amp supply can overheat a 30-amp cord going to a 30-amp boat, and a 30-amp supply can overheat a
15-amp cord. In principle, the boat has a breaker that is sized to prevent excess current coming from the pedestal, but that does not protect the cord itself, should the cord become damaged.

Of course, the offending short circuit that might escape traditional over-current protection must be in the Goldilocks range—not so small as to stay within the cord rating, and not a dead short that which would trip the breaker instantly. But this is possible.

For example, one of the plugs could become carbonized and begin heating. A minor chafe failure can also create a partial short that doesn’t trip the main breaker. This same risk is present with every household lamp; the cord is rated for less than 15 amps, but is plugged into 15-amp outlet. But there is an important difference—houses are not constantly moving, and living rooms are not exposed to weather.

In fact, extension cords routed under carpets, where they can build heat and chafe without anyone noticing it, are responsible for many house fires. This is why the American Boat and Yacht Council (ABYC) and the National Electronic Code (NEC) only allow step-down adapters for temporary use with power tools and accessories.

RISKS OF SHOREPOWER

Plugging a 15-amp boat into a 30-amp plug introduces two risks. First, there is overheating the cord. You can use a cord with a breaker on the male end to prevent this, but there is no way to weatherproof this plug where it connects to the 30-15 amp adapter. Power strips installed the boat end commonly have circuit breakers, but they do not protect the wire from a short caused by an exposed wire. The other risk of plugging a 15-amp boat into a 30-amp plug is a short introduced at the plug itself. A typical 15-amp plug does not have any weather-proofing features.

Both of the above problems can be solved by running a 30-amp cord direction into the boat cabin and then plugging in the 15-amp adapter, but you will still need overcurrent protection (a 15-amp breaker) on the boat.

Long term, the best answer is to install a 30-amp plug receptacle, breaker panel, and wiring in your small boat. The cost is about $500 in parts (inlet receptacle, basic panel, breakers, and wire). A professional installation would run about $1,000. I can see why it is not always done.

LIVING WITH 15-AMP RECEPTACLES

Ice melters are commonly plugged into 30 amp outlets using adapters. Some are plugged into 15-amp receptacles without special weatherproofing, and you can bet they are not inspected often in the winter. The ice melters typically have three-wire cords—either 12-gauge (12 AWG) or 14-gauge (14 AWG)—and these cords move just like a boat in a slip, but perhaps without the combustible fiberglass on the other end.

If your slip provides only a 15-amp receptacle, your choices are limited. I kept a 30-amp boat in a marina with 15-amp plugs for a decade.

I added a weatherproof hood to the outlet, wrapped the heavy duty 12-gauge (12 AWG) cord around a piling as strain relief, and spliced a 30-amp female pigtail to the boat end. To make the splice I used crimp connectors, heat shrink on each conductor, and two staggered layers of heat shrink over the cord to cover the insulated wires where the jacket was stripped away. And I always watch my amps like a hawk.

I also added an internally protected ground fault interrupt receptacle (GFI) on the dock pedestal and on the boat. Boaters should be aware that GFI outlets will trip occasionally from rain if the plugs are not protected by an outlet cover designed for protecing plugs while they are in in-use. Flapper-type covers protect the outlet, but are not weather proof when they are in-use.

Currently, I have a smaller boat with no shorepower receptacle, and I have the seasonal need to run a dehumidifier. Again, I added a weatherproof hood to the dock outlet. I use a heavy duty cord, wrap it around a piling for strain relief, and sneak it in through the companionway.

I provide a drip loop just inside the companionway. This is so that if any water should follow the cord into the boat, it drips into the bilge and doesn’t continue on to the plug end. The dehumidifier sits on the stove, where it can be left untended with very little fire risk. The tiny dehumidifier pulls less than one amp, so cord or plug heating is unlikely. Because they draw far more amps and are notorious for starting fires, I would never leave a heater unattended in this way.

OTHER SHORE POWER NOTES

No matter what type of connector or cord you are using, some simple precautions can help reduce the risk of fire or damage to the electrical system.

Connecting. Always turn the pedestal breaker off when connecting. If the supply breaker is not accessible, turn off the boat’s main breaker. Arcing damages the plug, and damaged plugs overheat.

Avoid salt contamination. If a plug falls in the water, unplug and remove immediately, rinse with tap water, and dry. Salt leads to corrosion, high resistance, shorting, and overheating.

Unplug. Never leave a shore power or extension cord plugged in to the pedestal when the boat is away. The other end can fall in the water, creating a hazard. Just a few minutes in saltwater will melt the end of the cord, generally without blowing the breaker. Unplug it from the pedestal.

Watch for pinch points. For example, it is common for a cord to get between a piling and a dockline and become chafed.

Alternatives. One of the best solutions to a sketchy shorepower setup is energy independence. Don’t plug in. A simple solar system, no more than a 50-watt panel and cheap charge controller, can free many smaller boats from the trouble of plugging in. It will handle some overnight cruises and can power the sump pump when dock power dies due to thunderstorms or ice storms. I have not depended on shorepower alone for 20 years, cruising boat, or day boat.

Heater risk. Of course, the greatest risk is leaving a space heater running in the winter. It can tip, something can fall into it, or it can just plain fail. Space heaters also run too close the limit for 15-amp plugs (they draw 12.5 amps at the 1,500-watt setting) for continuous service.

Avoid RV options. There are many cord adapter combinations that are acceptable for use on recreational vehicles. But this is different from boats. These vehicles are usually attended, and the RV is not constantly moving with the waves. Most likely, the cord is lying on gravel, where it poses minimal fire risk. Just because land yachts can use a product does not mean boaters should.

CONCLUSION

The best solution is to match the inlet to the available supply, but cruise a little and you will be faced with mismatches. Recognize the hazards introduced by every adapter and take steps to mitigate them.

If you have a 50-amp boat and must plug into a 30-amp pedestal, use locking connectors and keep a close eye on your power draw, trying hard to stay below about 20 amps (the most that is safe for continuous use). Same goes for a 30-amp boat plugged into 50 amps; use locking adapters and watch your cord for chafe.

Small boats may be best served by installing a small solar panel and not plugging in at all. If your marina caters to smaller boats and has 15 amp outlets rather than the 30-amp power pedestals required by the electrical code, at the very least make sure it is GFCI, that the cover is weatherproof in-use, and that you use a first quality #12 cord. Install it with strain relief and careful attention to chafe, and down-cycle it to yard use every few years, when the UV damage and wear first begin to show.

TECH GUIDE: COMPARING 15-AMP SHOREPOWER ADAPTERS

MANUFACTURER HALEX PARKWORLD MARINCO MARINCO MARINCO MARINCO TAYMAC 
DESCRIPTION 30-50 pigtail adapter 50-30 pigtail adapter Straight adapter Pigtail adapter Pigtail 3-plug adapter with GFI Pigtail adapter MM410C Cover and Receptacle 
RECEPTICAL 30 amps 30 amps 30 amps 30 amps 30 amps 15 amps 15 
PLUG 50 amps 50 amps 15 amps 15 amps 15 amps 30 amps NA 
WEATHERPROOF RECEPTACLE END Yes Yes No Yes No No Yes 
WEATHERPROOF PLUG END Yes Yes No No No Yes NA 
LOCKING RECEPTACLE END Yes Yes Yes Yes No No No but has partial restraint 
LOCKING PLUG END Yes Yes No No No Yes NA 
OVERCURRENT PROTECTION Yes No No No Yes Yes NA 
COMMENTS Watch your amps Wire not protected against overcurrent Wire not protected against overcurrent Wire not protected against overcurrent For use with tools; extension cords not protected against overcurrent Watch your amps, for temporary on-shore use only Any receptical that my be plugged in during rain should have an in-use cover 
MEETS NEC FOR SHOREPOWER Yes No No No No No No 
COMMENTS 
PRICE $46.00 $50.00 $42.00 $48.00 $96.00 $48.00 $11.00 
Rule Void for 15-amp Plugs Leaves Sailors Improvising

There is no shorepower standard or allowance for household-style 15-amp plugs of any kind. You can buy 15-amp inlets for bass boats, but they are only rated for use when out of the water. The two primary standards that guide shorepower hookups are ABYC Standard E-11 (American Boat and Yacht Council), and NEC article 555 (National Electrical Code).

CODE HIGHLIGHTS

• No receptacle less than 30 amperes (NEC).

• There must be strain relief for plugs and cords.

• Connectors must meet UL498M, which covers 20- to 50-amp, locking, weatherproof, grounded connectors (ABYC).

• The ENC lists the receptacles that are acceptable for providing weather protection. Makers often indicate this compliance.

• Each receptacle must have a separate breaker. The breaker or disconnect must be located within 30 inches of the receptacle (NEC).

• Connectors of locking and grounding type only.

• Boat-side receptacle must be weatherproof and locking, and also waterproof if subject to flooding.

• All 15- and 20-amp receptacles must be GFI type (5 mA leakage to trip). Beginning in 2011 GFI (also known as Equipment Leakage Circuit Interrupters) was expanded to include 30- and 50-amp circuits (30 mA to trip). Note that the 30mA shore power limit is six times the 5 mA limit that is required for for 15-amp circuits on power tools. So these receptacles are not sufficiently protective on their own. For example, at 16 amps muscles will spasm so that you can’t let go of the current carrying device or whatever conductor (bow rail, etc.) involved in the short, and at 30 mA breathing becomes impossible.

Ensuring Safe Shorepower

1. Marina power pedestals are typically fitted with one of the illustrated plug types (as represented in the ABYC Standards), one for each amperage rating. Cords rated at 30A and 50A are most common.

Ensuring Safe Shorepower

2. This example is about as bad as it gets for 15-amp service at a marina. There is no weather protection for the connector, the plug is botched, there’s no strain relief, and the cord is heavily chafed.

Ensuring Safe Shorepower

3. Probably the best available measure for protecting 15-amp service is a weatherproof cover that provides protection while the cord is plugged in. A few wraps around the piling provide strain relief.

Adapters to Suit Every Occasion

Sailors have a lot of options when choosing adaptors. We’ve tested products from Hubbel, Marinco, and Smartplug. All of the manufacturers in this field cater to both the recreational and the marine market.

Ensuring Safe Shorepower

1. Marinco’s straight adapter steps down from 30 amp to 15 amp. It does not lock in place.

Ensuring Safe Shorepower

2. Halex’s weatherproof 30-50A adapter is weatherproof, locking, and the downstream wire is larger than competitor’s adapters.

Ensuring Safe Shorepower

 

3. Marinco’s 30A-15A adapter has a locking plug at the receptacle end.

Ensuring Safe Shorepower

4. Parkworld’s 30A-15A pigtail adapter is similar to Marinco’s, but about $20 cheaper.

Ensuring Safe Shorepower

5. Parkworld’s pigtail 50Amp to 30 amp adapter has locking rings on both ends.

Ensuring Safe Shorepower

6. Marinco’s straight pigtail adapter drops 30 amps down to 15 amps. It has an indicator light that shows when it is energized.

Ensuring Safe Shorepower

7. Marinco’s pigtail adapter connects a dockside 15-amp outlet to 30-amp shorepower cord, with a locking connection at one end.

Ensuring Safe Shorepower

8. The Powerall extension cord has a a 15-amp breaker built into the plug.

A Rogues’ Gallery of Shorepower Plugs

Shore power mis-matches and 15-amp services are often hard to avoid, but you can make the best of it or you can create a real hazard. Here are several examples of disasters waiting to happen, some minor oversights, and some acceptable compromises.

Ensuring Safe Shorepower

1. At least the owner has made an effort to relieve strain at the adapter plug. The biggest problem, as it is with most 15-amp service challenges, is waterproofing.

Ensuring Safe Shorepower

2. Cover won’t close and cord is so tight, the plug is at an angle. The u-clamps supporting the cord should be padded to prevent chafe.

Ensuring Safe Shorepower

3. A weatherproof cover makes little sense if you can’t close it.

Ensuring Safe Shorepower

4. Here’s an outlet with GFI protection, strain relief, and a cover that can close with the cord in use. The cord could be a bigger size, and the 15-amp breaker is too far away.

Ensuring Safe Shorepower

5. Missing locking rings are common. They are replaceable.

Ensuring Safe Shorepower

6. This plug has no cover, no strain relief, and no strain relief.

Ensuring Safe Shorepower

7. The flapper-style receptacles are weatherproof only when closed, not while they are in use.

Ensuring Safe Shorepower

8. Many cords lack their locking rings despite them being easily replaced.

Ensuring Safe Shorepower

9. Oh dear. There is not a single thing done right here. The owner has made a feeble attempt at supporting the power cord, but both cords look to be in terrible conditions, with token electrical tape as a solution.

Ensuring Safe Shorepower

10. Another “oh, dear.” Anyone at this end of the marina had better have a fire extinguisher handy.

Drew Frye
Drew Frye, Practical Sailor’s technical editor, has used his background in chemistry and engineering to help guide Practical Sailor toward some of the most important topics covered during the past 10 years. His in-depth reporting on everything from anchors to safety tethers to fuel additives have netted multiple awards from Boating Writers International. With more than three decades of experience as a refinery engineer and a sailor, he has a knack for discovering money-saving “home-brew” products or “hacks” that make boating affordable for almost anyone. He has conducted dozens of tests for Practical Sailor and published over 200 articles on sailing equipment. His rigorous testing has prompted the improvement and introduction of several marine products that might not exist without his input. His book “Rigging Modern Anchors” has won wide praise for introducing the use of modern materials and novel techniques to solve an array of anchoring challenges. 

5 COMMENTS

  1. The article was focused on dockside (pedestal) misuse of 30- and 50-amp twist locks, and and on 15-amp alternatives. While SmartPlugs are becoming more common on boats, they are still very rare pedestals.

    That said, as Smart Plugs age we are starting to hear of scattered failures and one fire that we are aware of. Like other plugs, if they are not supported properly they can wear, corrode, and overheat. Twist locks can last decades if properly maintained. We are watching the issue, but please remember that a Smart Plug is not a cure-all for poor practices. You still need to keep the contacts clean and maintain proper support.

  2. I don’t understand how a higher amperage supply can burn out a lower amperage system that it is supplying, unless the lower amperage system tries to draw more than its rated amperage. A 50 amp supply only supplies as many amps as are demanded. If your boat demands a maximum of 30, you will have at most 30 amps going through a system rated for 30 amps, regardless of the capacity for the supply to provide more. The power being consumed and transmitted through the 30 amp system is 30 amps x 120 volts regardless of whether the supply is capable of supplying only 30 amps or could, if demanded, supply 50. Plug a 5 amp appliance into a 15 amp household circuit and you don’t burn it out; you still just draw 5 amps. If your 15 amp boat pulls into a harbour with 50 amp outlets, it still just draws up to 15 amps. Am I missing something?

  3. Easily. If a 30-amp cord or adapter is connected to a 50-amp pedestal, when a slight short develops in either the wire (chafe) or the plug (salt not flushed from the socket–very common) the current will exceed the rating of the wire, but not the rating of the pedestal breaker. Yes, the boat will only draw what the boat’s entrance breaker allows, but the cord and plug are not protected against any short on the land side of the boat entrance breaker. Overheated plugs and cords are common initiators for boat and dock fires.

    The 15-amp boat draws less than 15 amps, but the cord and plug can draw far more if damaged or contaminated with salt, followed by overheating and fire. Breakers are sized to protect the wiring, not the appliance.

    This is a common misunderstanding and was one of the primary motivations for writing the article.

  4. Okay, makes sense – for shorts and failures causing over-draw in the line compared to the boat’s wire rating but below the shore breaker rating. Thanks for the clarification. Although physical degradation from friction occasionally takes place, in my freshwater, 6 month environs you would almost never see corrosion of plugs or electrical hardware to any degree within a season. I guess one of the advantages of a short season is that all these systems get disconnected or reconnected twice a year, so potential problems are noticed relatively early.

    That said, I’ve noticed corrosion and physical degradation on the DC side from time to time, so I’ve added a lot of inline fuses to the 12 volt side of my boat. My bilge pump was wired directly to one battery with no fuse at all, for example, and I noticed some connectors corroding badly. Galvanic effect of DC voltage likely causes or adds to this problem, and it seems in the early 80’s very little attention was paid to the potential for low voltage wires to chafe or break, and most wires were not tinned either.

    Overall I’m in favour of less, rather than more, powered systems on a boat, so this trend to higher and higher shore power ratings seems to me to be going in the wrong direction; with electric vehicles and constantly increased tech, where are we going to get electrical power other than by further destructive fossil fuel burning? 50 amps is enough for a cottage or house, the idea of a washing and dryer and big screen TV on a recreational boat boggles my mind – hand wash in a pail and hang it on the lifelines to dry! But I digress …

    Cheers and safe sailing!